Fume hood
Fume hood

Fume hood

Price 385000.0 INR/ Unit

MOQ : 1 Unit

Fume hood Specification

  • Features
  • Chemical resistant body, low noise blower, fluorescent lighting, and electrical sockets
  • Glass Type
  • Toughened Glass Sash
  • Display Type
  • Analog Flow Meter
  • Shape
  • Rectangular
  • Control Type
  • Manual / Automatic Sash Option
  • Speed Range
  • Variable Sash Opening
  • Power Supply
  • Single Phase, 50 Hz
  • Temperature Resistance
  • Up to 120C
  • Type
  • Ducted Fume Hood
  • Dimension (L*W*H)
  • 1200 x 800 x 2300 mm
  • Equipment Type
  • Laboratory Fume Hood
  • Equipment Materials
  • Powder Coated Mild Steel / GI Sheet
  • Power
  • 2200 W
  • Voltage
  • 220 V
  • Material
  • Mild Steel, GI and Glass Combination
  • Application
  • Chemical laboratories, research labs, pharma companies
  • Front Sash
  • Counterbalance Weighted
  • Exhaust System
  • Centrifugal Blower Included
  • Lighting
  • Fluorescent Lamp 1 x 40 W
  • Color
  • Light Grey/Blue
  • Service Fittings
  • Available for Gas, Water, and Air
  • Sink & Tap
  • Polypropylene Sink with Water Tap
  • Gas and Vacuum Valves
  • Yes
  • Mobility
  • Fixed Type
  • Base Cabinet
  • Provided with Storage Cabinet
  • Internal Lining
  • Chemical-resistant lining
  • Optional Accessories
  • Carbon Filter, UV Lamp, Extra Power Sockets
  • Sash Movement
  • Vertical Sliding
  • Construction
  • Double Walled
  • Noise Level
  • < 65 dB
  • Worktop Material
  • Granite or Epoxy Resin
  • Baffle System
  • Aerodynamic Design for Smooth Airflow
  • Airflow Type
  • Horizontal/Vertical Flow
  • Maximum Face Velocity
  • 0.4 - 0.7 m/s
 

Fume hood Trade Information

  • Minimum Order Quantity
  • 1 Unit
  • Delivery Time
  • 5-7 Days
 

About Fume hood

Working Area : 1500 x 2350 x 850mm (L x H x W)
o Constructions: Cabinets is made of SS Sheet 304 Grade 1.2
mm mat.
o Interiors coated with fire proof epoxy paint.
o Working table is covered with 20 mm polished Granite.
o Door: Front door is made of 6mm clear Toughened glass.
o Counter weight balance Front Door.
o Vertical sliding facility & the front door can be stopped at any
point.
o Exhaust System: Exhaust blower consists of single phase
motor which is enclosed in a PVC casing connected with a
PVC Exhaust Ducting.
o Blower Details: POWER -70/60 W
o CFM -600 CFM
o AIR VOLUME -850 / 700 M3 PER HOUR STATIC PRESSURE -
350 / 280 Pa
o SOUND LEVEL -50 / 45 dB
o INLET & OUTLET SIZE -8" (200 mm) RPM = 2400 / 2500 RPM
o Electrical panel: main on off switch
o Illumination on off switch
o 15 amps Socket with on off switch Motor on/off switch
o Ducting: M.O.C 3 mm PVC Quantity 5 feet


Superior Construction and Chemical Resistance

Designed with a double-walled body using powder-coated mild steel or GI sheet, this fume hood ensures long-term durability. The internal lining and worktop-offered in granite or epoxy resin-are highly chemical resistant, protecting users and equipment from harsh reagents. The structure can endure temperatures up to 120C, making it ideal for a wide range of laboratory applications.


Efficient Airflow and Quiet Operation

Featuring an aerodynamic baffle system and included centrifugal blower, this fume hood achieves smooth airflow and effective contaminant removal. Face velocities range from 0.4 to 0.7 m/s, and noise levels remain below 65 dB, creating a comfortable workspace. Variable sash operation and a manual or automatic sash option add convenience and energy efficiency.


Easy Operation and Enhanced Safety

The vertical sliding, counterbalance sash is made from toughened glass to provide visibility and protection. Integrated service fittings for gas, water, and air, as well as a polypropylene sink with tap, support a variety of laboratory processes. The built-in storage cabinet and optional accessories-such as a carbon filter, UV lamp, and additional sockets-further promote safety and organization.

FAQ's of Fume hood:


Q: How does the fume hood's airflow system operate and what types are available?

A: The fume hood is equipped with either horizontal or vertical airflow, using an aerodynamic baffle system to ensure smooth and effective removal of hazardous fumes. The included centrifugal blower maintains variable face velocities between 0.4 - 0.7 m/s, supporting a clean and safe laboratory environment.

Q: What materials are used for the worktop and why are they beneficial?

A: You can choose between granite or epoxy resin worktops, both offering strong chemical resistance and high durability. These materials are ideal for laboratories conducting frequent chemical handling, as they protect against spills, scratches, and moderate heat exposure up to 120C.

Q: When should I use the manual versus automatic sash control option?

A: Manual sash controls are suited for general daily use and provide direct control over sash position, while automatic options are recommended for laboratories aiming to optimize energy efficiency and enhance operator safety, especially in high-volume or multi-user settings.

Q: Where can this fume hood be installed and what applications does it support?

A: This ducted fume hood is designed for installation in chemical laboratories, research institutions, and pharmaceutical companies. Its robust build and chemical-resistant features make it suitable for processes involving hazardous substances, ensuring user safety across diverse scientific fields.

Q: What is the procedure for routine maintenance and cleaning?

A: Routine maintenance involves regularly inspecting the airflow (using the analog flow meter), cleaning the worktop with suitable solvents, checking the chemical-resistant linings, and ensuring the centrifugal blower and lighting function properly. It is also important to periodically clean or replace optional carbon filters and check service fittings and valves for proper operation.

Q: How does the built-in storage and accessory options enhance user experience?

A: The integrated base storage cabinet allows safe and convenient storage of chemicals and lab tools, while optional accessories such as the UV lamp, carbon filter, and additional power sockets expand the utility and safety of the workstation, adapting the hood for varied experimental needs.

Tell us about your requirement
product

Price:

Quantity
Select Unit

  • 50
  • 100
  • 200
  • 250
  • 500
  • 1000+
Additional detail
Mobile number

Email

More Products in Laboratory Instruments Category

Rotary Vacuum Evaporator

Rotary Vacuum Evaporator

Price 80000.0 INR / Piece

Minimum Order Quantity : 1 Piece

Application : Distillation, Concentration, Solvent Recovery in Chemical, Pharmaceutical, and Research Laboratories

Material : Borosilicate Glass, Stainless Steel

Shape : Vertical Condenser Type

Features : Adjustable Rotation Speed, Digital Control, PTFE Sealing, Vacuum Controller Compatible, Overheat Protection

Electrochemical Workstations

Electrochemical Workstations

Price 800000.0 INR / Piece

Minimum Order Quantity : 1 Piece

Application : Electrochemical Analysis, Research Laboratories, Educational Institutes, Industrial Testing

Material : Metal, Plastic

Shape : Rectangular

Features : Multiple Modes (CV, CA, DPV, LSV, etc.), USB/RS232 Interface, Compact Design, Data Storage

Mitutoyo, Yuzuki Digital caliper

Mitutoyo, Yuzuki Digital caliper

Price 5000.0 INR / Unit

Minimum Order Quantity : 1 Unit

Application : Precision measurement of external, internal, step, and depth dimensions

Material : Stainless Steel

Shape : Straight with jaws

Features : Zero setting at any position, Metric/Inch conversion, Auto power off, Large display

Squidstat Decka Potentiostat

Squidstat Decka Potentiostat

Price 800000.0 INR / Unit

Minimum Order Quantity : 1 Unit

Application : Electrochemical analysis, battery research, corrosion, sensors, material characterization

Material : Metal body

Shape : Rectangular

Features : 10 independent channels, small footprint, compact design



Back to top