Glove box
Glove box
Glove box
Glove box

Glove box

Price 2100300.0 INR/ Piece

MOQ : 1 Piece

Glove box Specification

  • Shape
  • Rectangular
  • Accuracy
  • High sealing integrity (<1% leakage per hour)
  • Heating Capacity
  • Optional; up to 200 W
  • Display Type
  • Analog Pressure Gauge
  • Features
  • Leak proof, Transparent viewing window, Ergonomic access, Air-tight design
  • Glass Type
  • Borosilicate
  • Control Type
  • Manual / Automatic Purge Control
  • Temperature Resistance
  • Up to 150C
  • Power Supply
  • Electric
  • Type
  • Laboratory Glove Box
  • Dimension (L*W*H)
  • 1200 x 750 x 900 mm
  • Equipment Type
  • Glove Box
  • Equipment Materials
  • 304 Stainless Steel, Borosilicate Glass
  • Power
  • 230 V, 50 Hz
  • Voltage
  • 230V AC
  • Material
  • Stainless Steel & Glass
  • Application
  • Laboratory, Research, Chemical, Pharmaceutical
  • Capacity (Ltr)
  • 120 L
  • Air Lock Chamber
  • Inbuilt with separate access
  • Glove Material
  • Natural Rubber or Neoprene
  • Weight
  • Approx. 65 kg
  • Vacuum Gasket
  • Silicone, chemical-resistant
  • Purging System
  • Integrated with inflow/outflow valves
  • Working Atmosphere
  • Inert gas compatible (Nitrogen, Argon)
  • Humidity Control
  • Optional, available on request
  • Finish
  • Polished
  • No. of Glove Ports
  • 2
  • Lighting
  • Internal LED illumination
 

Glove box Trade Information

  • Minimum Order Quantity
  • 1 Piece
  • Delivery Time
  • 5-7 Days
 

About Glove box

Box:
Description material: Stainless steel 1.4301 (SUS type 304), 3mm thick Dimensions:
1200mm(L) x 750mm(W) x 900mm(H)
Overall weight approximately 600kg (excluding packaging) Volume 0.8 m3
Front window panel: 8 mm thick safety tempered glass or 10 mm thick polycarbonate (optional)
Size: 1123mm(L) x 839mm(H)
Glove mouth hard aluminium alloy or polyoxymethylene material (optional) Diameter 220 mm,
O-ring seal
Glove material: butyl rubber
Thickness: 0.4mm or 0.8mm(optional) Filter outlet and inlet filters, filter <0.3m
Lighting LED lighting is located at the top of the front window
Leakage rate leak detection in accordance with ISO 10648-2:1994 / EJ/T 1096-1999 "Sealed
box chambers - Part 2: The box was tested by the oxygen and pressure variation methods in
"Classification of airtightness and related testing methods", and the final acceptance test was
conducted in accordance with the standard of grade 1 airtightness < 0.001 vol%/h.
GP20 gas purification system
Describe the automatic removal of H2O and O2
Single purification column system, automatic regeneration (optional GP200 dual purification
column)
Closed gas circulation tubing
Operating voltage : AC 230V / 50-60Hz, 10A or AC 115V / 50-60Hz, 20A (optional) Working
gas : N2, Ar, He (purity 99.999%)
Regeneration gas: 5% - 10% H2, the rest is working gas (purity 99.999%)
Vacuum pump specification: Rotary vane vacuum pump with oil mist filter and gas ballast
control Flow rate: 12 m3/h (7 cfm), double base plate, vacuum < 2 x 10-3 mbar or dry pump
(optional)
Circulation unit oil-free high-speed fan
Air volume: 80 m3/h Valve KF40 high vacuum valve
Leakage rate leak detection in accordance with ISO 10648-2:1994 / EJ/T 1096-1999 "Sealed
box chambers - Part 2: The box was tested by the oxygen and pressure variation methods in
"Sealing Classification and related testing methods", and the final acceptance test was
conducted in accordance with the standard of grade 1 sealing
< 0.001 vol%/h.
Control cabinet size 600mm (L) x 800mm (D) x 870mm (H)
Transition compartment
Large transition chamber material: Stainless steel type 304 (1.4301), 3 mm thick Size
360mmx600mm(L) or 390mmx600mm(L)(optional)
Vacuum degree < 1 x 10-2 mbar
Small transition chamber material: Stainless steel type 304 (1.4301), 2 mm thick Dimensions
150mm x 330mm(L)
Vacuum degree < 1 x 10-2 mbar
Vacuum system
The vacuum pump is a British Edwards vacuum pump, model RV12, with a pumping speed of
12m3/h and an ultimate vacuum of 2x10-3 millibars. The transition chamber can be vacuumed
separately and can be controlled individually at any time. (Imported from abroad)
Cleaning system
When the corresponding time and pressure are set, the system can automatically displace
the gas in the tank.


Precision-Engineered Laboratory Glove Box

Our glove box is designed for maximum integrity and safety in laboratory and research environments. With high-quality components such as silicone vacuum gaskets, robust stainless steel, and borosilicate glass, it ensures reliable performance even under demanding conditions. An airtight construction and integrated purge system offer seamless management of inert atmospheres. Customizable options for humidity and heating provide further flexibility to suit diverse laboratory protocols.


Advanced Features and User-Centric Design

Equipped with dual glove ports, a separate air lock chamber, and internal LED illumination, the glove box delivers convenience and operational efficiency. Ergonomically positioned glove ports, manual and automatic purge controls, and a transparent viewing window improve user comfort and visibility. The system is also leak-proof, supporting high sealing accuracy and safety during sensitive chemical handling.

FAQ's of Glove box:


Q: How is the internal atmosphere controlled within this glove box?

A: The glove box maintains a controlled inert atmosphere using its integrated purging system, compatible with nitrogen or argon gases. Manual or automatic purge controls and silicone vacuum gaskets help maintain high sealing integrity with less than 1% leakage per hour.

Q: What applications is this glove box best suited for?

A: This glove box is ideal for laboratory, research, chemical, and pharmaceutical applications where a controlled, moisture-free, and oxygen-free environment is essential for handling sensitive materials.

Q: Where is the air lock chamber located, and how is it used?

A: The inbuilt air lock chamber is positioned on the glove box and features separate access, allowing users to transfer materials in and out without compromising internal atmosphere quality.

Q: What materials are used in the glove box construction and why?

A: The glove box is constructed from 304 stainless steel and borosilicate glass for durability, chemical resistance, and easy cleaning. The gloves are available in natural rubber or neoprene, ensuring both comfort and chemical compatibility.

Q: When is humidity control necessary, and how can it be added?

A: Humidity control becomes essential when handling moisture-sensitive samples. It is an optional feature, available upon request, to further refine internal environmental conditions.

Q: How does the glove box ensure user visibility and safety during operation?

A: The glove box has a polished finish, transparent borosilicate glass viewing window, and internal LED lighting for clear visibility. Its leak-proof design and high sealing accuracy protect users from chemical exposure.

Tell us about your requirement
product

Price:

Quantity
Select Unit

  • 50
  • 100
  • 200
  • 250
  • 500
  • 1000+
Additional detail
Mobile number

Email

More Products in Laboratory Instruments Category

Incubator BOD

Incubator BOD

Price 200000.0 INR / Unit

Minimum Order Quantity : 1 Unit

Type : Other, BOD Incubator

Shape : Rectangular

Power : 230V AC, 50 Hz

Dimension (L*W*H) : 600 x 600 x 875 mm

Vaccum Oven

Vaccum Oven

Price 80000.0 INR / Unit

Minimum Order Quantity : 1 Unit

Type : Other, Vaccum Oven

Shape : Rectangular

Power : 800 W

Dimension (L*W*H) : 490 x 590 x 630 mm

Fume hood

Fume hood

Price 385000.0 INR / Unit

Minimum Order Quantity : 1 Unit

Type : Other, Ducted Fume Hood

Shape : Rectangular

Power : 2200 W

Dimension (L*W*H) : 1200 x 800 x 2300 mm

Laser Raman Spectrometer

Laser Raman Spectrometer

Price 830000.0 INR / Number

Minimum Order Quantity : 1 Number

Type : Other, Laser Raman Spectrometer

Shape : Rectangular

Power : < 60 W

Dimension (L*W*H) : 360 mm x 263 mm x 130 mm



Back to top